The emissions per MJfuel burned by a centralized boiler technology are calculated from Ecoinvent V2.2 [1]. The selected data sets are:
Gas | natural gas, burned in industrial furnace low-NOx >100kW, RER, [MJ] |
---|---|
Oil | light fuel oil, burned in industrial furnace 1MW, non-modulating, CH, [MJ] |
Wood | wood chips, from forest, hardwood, burned in furnace 1000kW, CH, [MJ] |
Coal | hard coal, burned in industrial furnace 1-10MW, RER, [MJ] |
Waste | municipal solid waste, to municipal incineration, CH, [kg] * |
*LHVwaste = 11.74 MJ/kg
[1] Ecoinvent V2.2