 +====== Decentralized boiler emissions ======
 +The emissions per MJ<sub>fuel</sub> burned by a [[d_boiler|decentralized boiler technology]] are calculated from Ecoinvent V2.2 <sup>[[#References|[1]]]</sup>. The selected data sets are:
  
 +^Gas |natural gas, burned in boiler condensing modulating <100kW, RER, [MJ] |
 +^Oil |light fuel oil, burned in boiler 10kW condensing, non-modulating, CH, [MJ] |
 +^Wood |wood chips, from forest, hardwood, burned in furnace 50kW, CH, [MJ] |
 +
 +===== References =====
 +[1] [[http://www.ecoinvent.ch/|Ecoinvent V2.2]]