+ | ====== Direct electric heating emissions ====== | ||
+ | The emissions per kWh of heat supplied are equal to the sum of the emissions related to the electricity production and distribution plus the emissions of the production, installation and decommissioning of the direct electric heating system. | ||
+ | |||
+ | The emissions related to the electricity supply (production& | ||
+ | |||
+ | The emissions related to the production, installation and decommissioning of a direct electric heating system come from the Ecoinvent V2.2 dataset < | ||
+ | |||
+ | ^CO< | ||
+ | ^Deposited waste [UBP/unit] |1423 | | ||
+ | |||
+ | Knowing the capacity factor (0.3) and the life time of the system (25 years), the emissions per kWh of heat supplied can be calculated: | ||
+ | |||
+ | ^CO< | ||
+ | ^Deposited waste [UBP/ | ||
+ | |||
+ | If these emissions are compared to those for the actual electricity supply in Switzerland (0.125 kgCO< | ||
+ | |||
+ | ===== References ===== | ||
+ | [1] [[http:// | ||