 +====== Centralized direct electric heating ======
  
 +Next tables contain the economic parameters that have been introduced in the [[c_direct_elec|Centralized direct electric heating]] model.
 +
 +^  Specific investment [CHF<sub>2010</sub>/kW<sub>e</sub> ^^
 +^  ^  2011-2050  ^
 +^MIN |243 <sup>[[#References|[1]]]</sup>|
 +^MID |284 <sup>[[#References|[1]]]</sup>|
 +^MAX |365 <sup>[[#References|[1]]]</sup>|
 +
 +^  [[o_m_cost|O&M cost]] [CHF<sub>2010</sub>/kW<sub>e</sub> ^
 +^  2011-2050  ^
 +|14 <sup>[[#References|[1]]]</sup>|
 +
 +^[[life_time|Lifetime]] [years] |15 <sup>[[#References|[1]]]</sup>|
 +
 +
 +===== References =====
 +[1] [[http://www.rhincentive.co.uk/library/regulation/0907Heat_Supply_Curve.pdf|NERA & AEA (2009), The UK Supply Curve for Renewable Heat, Study for the Department of Energy and Climate Change.]]