The emissions per MJfuel burned by a dentralized cogeneration technology are calculated from Ecoinvent V2.2 [1]. The selected data sets are:
Gas | microGT | natural gas, burned in micro gas turbine 100kWe, CH, [MJ] |
---|---|---|
50kWe | natural gas, burned in cogen 50kWe lean burn, CH, [MJ] | |
160kWe | natural gas, burned in cogen 160kWe lambda=1, CH, [MJ] | |
Oil | diesel, burned in cogen 200kWe diesel SCR, CH, [MJ] | |
Wood pellets | wood pellets, burned in stirling cogen unit 3kWe, future, CH, [MJ] |
[1] Ecoinvent V2.2